Axicon PC6500 Series Barcode Verifiers
|
TECHNICAL SPECIFICATIONS: |
|
THE RANGE
| |
|
PC-6500 | Standard Model
|
|
PC-6505 | Product Look Up Option - links the software to any database so that when you scan the barcode you get a description of the product that the bar code should relate to as well as the quality control information.
|
|
PC-6510 | UCC/EAN-128 Data Content Checker - gives the user descriptions of the application identifiers used and then validates the information following, checking for possible structure and content errors (e.g. date errors, check digit errors, incorrect field lengths etc). CSV File Storage - enables verified data to be stored to disk as a c.s.v. text file to enable the user to analyse their results using Excel, Lotus or any similar Windows spreadsheet program. - can be set to record all data automatically if required.
|
|
PC-6515 | All of the above features.
|
|
SOFTWARE SPECIFICATIONS
| |
|
Windows based program | free updates for life. Latest software updates can be downloaded from www.axicon.com.
|
|
Symbologies Verified | RSS (all symbologies), EAN-8/EAN-13 and UPC-A/UPC-E (with or without addons), ITF/Case Code, Code 39,Code 39 ASCII, Codabar, Code128, UCC/EAN-128, Italian Pharmacode, HIBC.
|
|
Analysis on relevant Symbologies | Full ISO/CEN/ANSI Parameter Analysis - Rmax, Rmin, Global Threshold, Symbol Contrast, Defects, Decodability,Decode, Full Traditional Verification - Print Contrast Measurement (PCS) and Nominal Bar Width Analysis, Light Margin Validation, Check Digit Verification, Data Length, Parity, Control Characters and Structure Checking, Wide to Narrow Bar Ratio Display and Verification, Full Data Encodation including Subsets & Start/Stop Characters, Full Bar/Space Dimensional Analysis/Decodability per Character Set (to ISO standards).
|
|
Diagnostic screens | Command screen, Summary and Details results screens, Pass/Fail screen / Traditional results screen, Scan Reflectance Profile, Static Scan Reflectance, Dimensional Analysis. Options: UCC/EAN-128 Data Content, Product-Look-Up Table.
|
|
Logging | Scan Storage and Replay - stores reflectance values to enable playback of data and remote diagnostics.
|
|
Calibration Logging | A record of date and time to show when the hardware has been calibrated is kept. Especially important for ISO9000 records.
|
|
User Settable Features | Time and Date (through Windows), Reflectance Calibration, Pass/Fail Grade, Settable Multi-Scan Averaging.
|
|
Error Messages | Audible Warnings, User-Changeable Warning Colours, Check Digit Error, Structure Error, Light Margin Error, Reference Decode Algorithm Error.
|
|
Plugins available | See seperate sheet.
|
|
HARDWARE SPECIFICATIONS
| |
|
Dimensions | 145 x 113 x 128 mm, Scan Width - 125mm (including light margins)
|
|
Weight | 675g
|
|
Construction | Interface Unit - Black plastic
|
|
Interface | RS232C Serial to PC Computer
|
|
Power | Current Draw - 140mA, External Power Required (supplied with PS2 cable to take power from keyboard port - optional AT/XT cable or 5V Regulated PSU available)
|
|
Nominal Measuring Aperture | 150microns (6mil). Automatically identifies symbology and nominal bar size (X dimension) and adjusts aperture size automatically in accordance with symbology specifications and International Standards to ensue accurate verification between 125micron (5ml), 150 micron (6ml), 250 microns (10ml) and 500 microns (20ml).
|
|
Wavelength of Light | 660 nanometers.
|
|
GENERAL INFORMATION
| |
|
Print of Analysis | A printed analysis can be produced on any printer for which a Windows? driver is available, (dot-matrix,ink-jet, laser or thermal transfer). The printout will be automatically resized to suit the output media size,enabling verification reports to be printed on self-adhesive labels if required. Printouts can be produced for: the main verification information*, scan reflectance profiles and also for the UCC EAN-128 data content information.*(includes: Time & Date, Number of Scans, Code Type, Average ANSI/CEN Grade, Average Bar Gain,Magnification, Check Character, Light Margin, Scan Analysis and Grading Percentage Values)
|
|
Standard Accessories | Transit Case, Bar Code Scale Rule, DB9 Serial Interface Cable, Power Input Cable (PS2), Calibration Sheet and Startup Guide.
|
|
System Requirements | IBM or compatible PC (486 or higher preferred), running Windows 95 or higher.
|
|